An air handler that is leaking water on the floor may be the result of a few issues.
Attic air handler leaking.
Water is produced as a byproduct of the cooling system and typically drains away from the house through a hose or pipe.
If you notice water under your indoor air handler turn off the air conditioner at the breaker box and either call a professional or follow these steps.
It is code in many states to have a secondary drain pan and secondary drain pan safety switch installed on all attic air handlers and furnaces.
The air handler itself should have a secondary drain pan installed under the air handler in case if the air handler leaks then the secondary drain pan will catch the condensate and take it to another drain.
Air conditioning systems are made up of two separate components the condenser or outdoor unit and the air handler or indoor unit.
Since the air conditioner evaporator coil inside the air handling unit operates at a temperature less than the dew point it will condense the.
There are only a few causes of a leaking air conditioner the first one being a clogged air filter.
A malfunction anywhere in this system can cause an air handler to not dispose of water properly and result in water overflowing onto the floor.
With these systems condensate leaks can lead to a big mess but it s nothing compared to a condensate leak that occurs at an air conditioner in an attic or really any place that has finished.
The indoor ac unit in many phoenix area homes is attached to your furnace and located in the attic.
Improper or no insulation of ducts.
Is your air conditioner leaking water inside or outside your house or business.
Therefore your ceiling leak may appear to be originating from your furnace when it is actually coming from.
Chances are your ceiling has the equivalent of a 2 ft.
When your air filter is dirty air cannot pass through as easily.
This is a list of the top 10 reasons that your ac unit may be leaking water inside or outside of your residential or commercial property in 2018 2019.
Square hole that s acting like a chimney drafting expensive heated.
Small air leaks into uninsulated attic space are a major source of heat loss in many homes.
Never leave water standing around your air conditioner.
If you have a problem with water in your air conditioner s drain pan call del air heating and air conditioning at 844 574 4578 for efficient ac troubleshooting that will help you solve the problem.
Checking the air handler condensate lines air handler leaking in attic prevention checking the air handler condensate lines is especially important if your air handler is located in the attic.
Excessive condensation from air conditioning is a sign you have an ac issue.